INLET & PRETREATMENT
Check incoming water quality and determine whether suspended solids, chlorine or other substances need to be removed before the resin stage.
Shivsu Watec DM plants use ion-exchange technology to remove dissolved mineral ions from water. Each configuration is selected around incoming water quality, required capacity and the purity needed for the intended process.
A demineralization plant lowers the dissolved mineral content of water using ion-exchange resins.
Water can contain dissolved minerals and salts such as calcium, magnesium, sodium, chlorides and sulphates. In applications that require low mineral content, these ions may need to be removed before the water is used.
A conventional DM plant passes water through cation and anion exchange resins. The configuration and any additional polishing stages depend on incoming water quality and the purity required for the intended application.
Remove a broad range of positively and negatively charged ions.
Select the treatment arrangement around the quality needed by the process.
Match plant design to source-water quality and required treated-water flow.
Ion-exchange stages remove dissolved cations and anions. Pretreatment and additional polishing can be included when the raw water or application requires them.
Check incoming water quality and determine whether suspended solids, chlorine or other substances need to be removed before the resin stage.
Cation resin removes positively charged ions, including calcium, magnesium and sodium.
Anion resin removes negatively charged ions, including chlorides and sulphates.
Collect treated water after the required treatment stages and check whether it meets the application's water-quality requirements.
When the resins reach their operating capacity, regenerate them with suitable chemicals to restore ion-removal performance.
System note — The need for pretreatment, polishing and regeneration depends on incoming water quality, resin capacity, operating conditions and the target water quality.
Many industries use demineralization plants where water with very low mineral content is required. The final system configuration should be selected for the specific process and its water-quality targets.
Provide low-mineral water where boiler feed requirements call for demineralization.
Support industrial processes that require controlled mineral content.
Supply treated water for textile operations with defined water-quality needs.
Support water requirements for power-generation processes.
Help meet low-mineral water requirements for laboratory applications.
Configure treatment around the water-quality requirements of the intended process.
Provide water with reduced dissolved ions for suitable production processes.
Select treatment stages based on source water and required purity.
DM plant sizing depends on both the water entering the system and the quality required at the outlet. Capacity, peak demand and resin regeneration also influence the design.
Identify the dissolved-ion profile and determine whether pretreatment is needed.
Account for water consumption, operating hours and peak flow requirements.
Set the treated-water quality according to the intended application.
Consider resin operating capacity and the requirements for chemical regeneration.
Include polishing or other treatment when the application needs a higher level of purity.
Shivsu Watec helps evaluate demineralization options around incoming water quality, flow requirements and the purity needed by the application.
Consider raw water analysis, intended use and required treated-water quality.
Account for daily consumption, peak flow and operating conditions.
Evaluate the water requirements of boilers, manufacturing and other industrial processes.
Include resin capacity and regeneration needs as part of the system selection.
Answers about DM plant operation, water quality, capacity and regeneration.
A water softener mainly removes calcium and magnesium ions that cause hardness. A DM plant removes a wider range of dissolved cations and anions, reducing the overall mineral content of the water.
A conventional DM plant removes dissolved ions, but it does not disinfect water or remove bacteria as its primary function. If microbiological control is required, additional filtration or disinfection can be added.
Capacity depends on incoming water quality, water consumption, operating hours, peak demand and the level of purity needed. A water analysis helps determine a suitable plant design.
There is no single schedule for every system. Regeneration depends on incoming water quality, resin capacity, water consumption and operating conditions. Monitoring treated-water quality helps determine when regeneration is needed.
Yes. Some applications need a higher level of purity, so additional treatment or polishing systems can be included when required by the application.
Share your raw water analysis, required flow rate and intended application. These details help assess a demineralization configuration suited to your water-quality requirements.